Get a quote in 24h
Menu

Free sample

Arc flash study sample report PDF: see exactly what you get

US arc flash studies, PE-reviewed, quoted in 24 hours. Judge the deliverable before you commit.

  • PE-reviewed
  • Built on current NFPA 70E-2027
  • IEEE 1584-2018
  • Field engineers travel to every US state
  • Written quote in 24 hours

An arc flash study sample report PDF shows the deliverable before you buy: the one-line diagram, the incident energy table for every bus, the label printed for each piece of equipment, mitigation options and the PE review. Ours is anonymised from real work. Request it below and it reaches your inbox by email.

What the sample report shows

Get the full sample report

  1. One-line diagram

    Every bus, transformer and protective device in scope, drawn from field-verified data.

    [PENDING: anonymised sample report excerpt]

  2. Incident energy table

    Incident energy, arc flash boundary and PPE category for each bus, with the working distance used.

    [PENDING: anonymised sample report excerpt]

  3. Arc flash label

    The label printed from the study data for each assessed piece of equipment.

    [PENDING: anonymised sample report excerpt]

Send me the full PDF

Inside an arc flash study report

An arc flash study report is the document your team works from for five years. It states the standards and method, lists every bus with its fault current, clearing time, incident energy, boundary and PPE, explains the assumptions, ranks mitigation options, and records the PE review. If a section is missing, your auditor will notice before you do.

Sections in every report
SectionWhat it contains
Basis and methodStandards and editions: IEEE 1584-2018, NFPA 70E-2027
System descriptionOne-line diagram and data sources
Short circuit resultsAvailable fault current in kA at each bus
Incident energy tableIncident energy in cal/cm², boundary in in, PPE
MitigationOptions that lower incident energy at high-energy buses
LabelsLabel content for each assessed piece of equipment

Arc flash study report PDF, built to be used

Your arc flash study report PDF is searchable, bookmarked by section, and organized so an electrician can find a bus in seconds. Ask for the model file and the label register as well, so the next review starts from your data instead of from scratch.

An arc flash study example, start to finish

This arc flash study example follows one bus through the report: the field data verified on site, its place on the one-line diagram, the fault current, the protective device that clears it, the incident energy and boundary, and the label that results. The sample report shows that full chain for every bus in scope.

Sample one-line diagram with incident energy One-line diagram. Utility source feeds SWGR-1 at 13.8 kV, then main transformer T1 (13.8 kV to 480 V) feeds SWGR-2 at 480 V. SWGR-2 feeds MCC-1A and MCC-1B at 480 V and transformer T2 to panelboard LP-1 at 208 V. Incident energy: SWGR-1 6.1, SWGR-2 32.4, MCC-1A 4.9, MCC-1B 2.7, LP-1 1.4 cal/cm². Sample, illustrative values. One-line diagram Sample, illustrative values UTILITY SOURCE SWGR-1 · 13.8 kV T1 13.8 kV / 480 V SWGR-2 · 480 V T2 480 / 208 V MCC-1A480 V MCC-1B480 V LP-1208 V 6.1 cal/cm² 32.4 cal/cm² 4.9 cal/cm² 2.7 cal/cm² 1.4 cal/cm² Incident energy at working distance: 36 in at 13.8 kV, 18 in at 480 V and 208 V.

Frequently asked questions

Question not here? Ask an engineer

What should an arc flash study report include?

An arc flash study report should include the standards and editions used, the one-line diagram, data sources and assumptions, short circuit results, protective device settings, incident energy and boundary at every bus, PPE, mitigation options, label content, and a record of the PE review. Our sample report shows all of them.

Can you provide an example of an arc flash study?

Yes. Request the sample report with the form on this page and we email an anonymised arc flash study example within one business day. It is drawn from real work, with names, sites and identifying values removed, so you see the exact format and depth your own report will have.

What does an arc flash analysis example look like?

An arc flash analysis example is a table, one row per bus: voltage, bolted fault current, arcing time, incident energy at the working distance, arc flash boundary and PPE. The graphics on this page show the format with illustrative values; the emailed sample shows a full table from an anonymised study.

Why is the full report sent by email instead of posted here?

The report is anonymised from real projects, and we keep it off the open web so it is not copied, scraped or mistaken for a template. Email delivery also lets an engineer follow up if you have questions about your own site and how its report would differ.

Is the sample report free?

Yes, completely. There is no charge and no obligation. Ask for it, read it, and if the format suits your team, request a quote for your own site. If it does not, keep the sample as a benchmark when you compare other providers.

Will our report look the same as the sample?

Yes, the same structure and depth, built around your system. The number of buses, the mitigation options and the labels will reflect your site, and we can add sections your auditor or insurer requires, such as a coordination appendix or a maintenance note.

Get the full sample report by email

Tell us about your facility. An engineer replies within one business day with scope, timeline and price.

  • IEEE 1584-2018 and NFPA 70E-2027, PE-reviewed
  • Labels and training in the same scope
  • Field engineers travel to any US state
Get a quote in 24h